What's New in ScreenShaper Software Version 2.00 Copyright (c) 2003 by Folsom Research, Inc., All Rights Reserved. Thank you for using the ScreenShaper products (VMS-100 or VMS-1000). This What's New file contains important information regarding this release. Folsom Research strongly recommends that you read the entire document. Folsom Research welcomes your comments and suggestions. Please use the information provided in this file to contact Customer Service or Technical Support. Note: When printing this document, choose Landscape for page orientation. ___________________ WHAT'S IN THIS FILE - New Features - Improved Functionality - Installation - Contacting Folsom Research, Inc. ******************** Version 2.00 *************************** ____________ NEW FEATURES - Additional input and output resolutions: 1280x720, 1280x768 and 1280x960. Note that keystoning for these resolutions is not supported. - New command: IRSP command is added to adjust the input raster. ______________________ IMPROVED FUNCTIONALITY - Change the meaning of CAP command. CAP command is to define the capture region of the input raster. This command allow the user to zoom into a region of the input raster. Note that CAP is only available in the Rotation Mode. - Limit TLCK to cases where the input and output resolution and frame rate matches. ******************** Version 1.05 *************************** ______________________ IMPROVED FUNCTIONALITY - Improved start up sequence. ******************** Version 1.04 *************************** ____________ NEW FEATURES - Addition of Rotation functions into the ScreenSHAPER products. These functions (Rotation, Flip and Display Area) are enabled by selecting the Rotate Operation Mode under System Setup Menu - DVI input format is automatically detected. - New output frame rate of 59.94Hz. - Added the Gamma Correction to the front panel menu. - Black Level Adjustment of Non-blended region has been added to the Edge Feather Submenu. ______________________ IMPROVED FUNCTIONALITY - The system variables are only reset to default if version number change from 1.XX to 2.XX. The settings of the unit will be preserve on minorsoftware upgrades. - Fix the problem of where the RS232 Config were not saved correctly in the previous version. - Fix scaling routine to be capable of scaling image more than 50%. ******************** Version 1.03 *************************** ____________ NEW FEATURES - Addition of capability to load and store 9 user-defined warp maps that can be recalled with the MAP command. WARP MAP INDEX has been added in the ScreenSHAPER VMS-100 front panel's output setup menu. - The input auto detection distinguishes between 59HZ, 60HZ, 75HZ and 85HZ. Note the H Frequency for 59HZ and 60HZ are close and can be mistaken one for another. In which case, it is require to adjust the H Total, H Start and V Start for proper input sampling. ______________________ IMPROVED FUNCTIONALITY - Front Panel control of HTotal increments/decrements by 2. - In addition to output XGA, support keystone warping for output SXGA and SVGA. ******************** Version 1.02 *************************** ____________ NEW FEATURES - First release for ScreenShaper VMS-1000. - For ScreenShaper VMS-100, new mode of warping, "KEYSTONE", where the image is corrected for off-axis projection of 0 to 25 vertical degree and -20 to 20 horizontal degree. "V KEYSTONE" and "H KEYSTONE" are added to the Output Setup menu to select the desired degree of keystone. Each index represents a change of 2.5 degree. - RESET command has a new parameter, "F", which restores all system variables to the default settings and reset the gamma LUT that was saved for projector light intensity calibration. ______________________ IMPROVED FUNCTIONALITY - Fixed occassional error where enabling the output raster box on digital input will cause the lost of the image. ____________ INSTALLATION Refer to the upgrade_instructions.txt file contained in the VMS1000_Rev###.exe file for instructions on upgrading your ScreenShaper system to this release of software. __________________________ CONTACTING FOLSOM RESEARCH Should you have any comments or questions about this release or any other product, please contact the factory using one of the following methods: ____________________ In the United States Toll Free: 1-888-414-SCAN 7226 Phone Number: 1-916-859-2500 Tech Support: 1-866-FRI-SUPT (24hours/7days) 1-866-374-7878 FAX: 1-916-859-2515 EMAIL: support@folsom.com _________ In Europe Folsom Research BV: Chromiumweg 111 3812 NM Amersfoort The Netherlands T: +31 33 4651555 F: +31 33 4627500 M: +31 6 20005591 EMAIL: saleseurope@folsom.com